File: //usr/share/mof/cimv2.33.0/Metrics/CIM_BaseMetricValue.mof
// Copyright (c) 2008 DMTF. All rights reserved.
[Version ( "2.19.0" ),
UMLPackagePath ( "CIM::Metrics::BaseMetric" ),
Description (
"Each CIM_BaseMetricValue object represents the instance value "
"of a metric. Since the gathering of metric information can "
"involve large quantities of information there may be many "
"instances of this class. The use of this class as an "
"instrumentation source may be inefficient unless the rate of "
"metrics are known. The length of time a CIM_BaseMetricValue "
"instance exists after the metric information is captured is "
"not defined and is implementation dependent. \n"
"Most metric data values change over time. There are two ways "
"of mapping this into CIM_BaseMetricValue objects: The value "
"for the next point in time may use the same object and just "
"change its properties (such as the value or timestamp), or the "
"existing objects remain unchanged and a new object is created "
"for the new point in time. The first method is typically used "
"for snapshot data and the second method for historical data. "
"Which method is used, is indicated by the Volatile property." )]
class CIM_BaseMetricValue : CIM_ManagedElement {
[Key, Override ( "InstanceID" ),
Description (
"Within the scope of the instantiating Namespace, "
"InstanceID opaquely and uniquely identifies an instance "
"of this class. In order to ensure uniqueness within the "
"NameSpace, the value of InstanceID SHOULD be constructed "
"using the following \'preferred\' algorithm: \n"
": \n"
"Where and are separated by a colon \':\', and where MUST "
"include a copyrighted, trademarked or otherwise unique "
"name that is owned by the business entity "
"creating/defining the InstanceID, or is a registered ID "
"that is assigned to the business entity by a recognized "
"global authority (This is similar to the <Schema "
"Name>_<Class Name> structure of Schema class names.) In "
"addition, to ensure uniqueness MUST NOT contain a colon "
"(\':\'). When using this algorithm, the first colon to "
"appear in InstanceID MUST appear between and . \n"
"is chosen by the business entity and SHOULD not be "
"re-used to identify different underlying (real-world) "
"elements. If the above \'preferred\' algorithm is not "
"used, the defining entity MUST assure that the resultant "
"InstanceID is not re-used across any InstanceIDs "
"produced by this or other providers for this instance\'s "
"NameSpace. \n"
"For DMTF defined instances, the \'preferred\' algorithm "
"MUST be used with the set to \'CIM\'." )]
string InstanceID;
[Required, Description (
"The key of the BaseMetricDefinition instance for this "
"CIM_BaseMetricValue instance value." ),
ModelCorrespondence { "CIM_BaseMetricDefinition.Id" }]
string MetricDefinitionId;
[Description (
"A descriptive name for the element to which the metric "
"value belongs (i.e., the measured element). This "
"property is required by behavior if there is no "
"association defined to a ManagedElement, but may be used "
"in other cases to provide supplemental information. This "
"allows metrics to be captured independently of any "
"ManagedElement. An example is where a metric value "
"belongs to a combination of elements, such as the input "
"and output ports of the traffic in a switch. If there "
"are multiple ManagedElements associated with the metric "
"value, then usually there is one that naturally belongs "
"to the metric value and that one should be used to "
"create the supplemental information. The property is not "
"meant to be used as a foreign key to search on the "
"measured element. Instead, the association to the "
"ManagedElement should be used." )]
string MeasuredElementName;
[Description (
"Identifies the time when the value of a metric instance "
"is computed. Note that this is different from the time "
"when the instance is created. For a given "
"CIM_BaseMetricValue instance, the TimeStamp changes "
"whenever a new measurement snapshot is taken if Volatile "
"is true. A managmenet application may establish a time "
"series of metric data by retrieving the instances of "
"CIM_BaseMetricValue and sorting them according to their "
"TimeStamp." ),
ModelCorrespondence { "CIM_BaseMetricDefinition.TimeScope",
"CIM_BaseMetricValue.Duration" }]
datetime TimeStamp;
[Description (
"Property that represents the time duration over which "
"this metric value is valid. This property should not "
"exist for timestamps that apply only to a point in time "
"but should be defined for values that are considered "
"valid for a certain time period (ex. sampling). If the "
"\"Duration\" property exists and is nonNull, the "
"TimeStamp is to be considered the end of the interval." ),
ModelCorrespondence { "CIM_BaseMetricDefinition.TimeScope",
"CIM_BaseMetricValue.TimeStamp" }]
datetime Duration;
[Required, Description (
"The value of the metric represented as a string. Its "
"original data type is specified in "
"CIM_BaseMetricDefinition." )]
string MetricValue;
[Description (
"If present, specifies one BreakdownDimension from the "
"BreakdownDimensions array defined in the associated CIM_ "
"BaseMetricDefinition. This is the dimension along which "
"this set of metric values is broken down. For a "
"description of the concept, see the class "
"CIM_BaseMetricDefinition." )]
string BreakdownDimension;
[Description (
"Defines a value of the BreakdownDimension property "
"defined for this metric value instance. For instance, if "
"the BreakdownDimension is \"TransactionName\", this "
"property could name the actual transaction to which this "
"particular metric value applies." )]
string BreakdownValue;
[Description (
"If true, Volatile indicates that the value for the next "
"point in time may use the same object and just change "
"its properties (such as the value or timestamp). If "
"false, the existing objects remain unchanged and a new "
"object is created for the new point in time." )]
boolean Volatile;
};